REST Mode ​

REST mode allows v2c-any to emulate a Shelly Pro EM energy meter by exposing a REST API that V2C wallboxes can poll. This makes v2c-any act as a drop-in replacement for physical Shelly hardware.

When to Use REST Mode ​

Use REST mode when:

  • Your V2C wallbox is configured to poll a Shelly Pro EM meter
  • You want to replace physical Shelly hardware without reconfiguring your wallbox
  • You prefer a pull-based (polling) approach
  • You don't have or don't want to set up an MQTT broker
  • You're testing or simulating meter behavior

Don't use REST mode when:

  • Your V2C wallbox is already configured for MQTT (use MQTT mode instead)
  • You need very low latency updates (MQTT is faster)
  • You want push-based event-driven updates

How It Works ​

  1. v2ca starts a Fastify HTTP server
  2. Exposes endpoints matching the Shelly Pro EM API format (/rpc/EM1.GetStatus)
  3. V2C wallbox polls the endpoint at configured intervals
  4. Returns real-time power data from your configured sources

Configuration ​

yaml
provider: rest
properties:
  port: 3000 # HTTP server port
  meters:
    grid:
      feed:
        type: http-adapter
        properties:
          device: shelly-pro-em
          host: 192.168.1.100
    solar:
      feed:
        type: mock
        properties:
          value:
            id: 1
            act_power: 2500
            calibration: factory

HTTP Server Options ​

OptionTypeRequiredDefaultDescription
portnumberYes-Port for the HTTP server (e.g., 3000, 8080)

HTTP Adapter Feed Options ​

OptionTypeRequiredDefaultDescription
devicestringYes-Device type (currently: shelly-pro-em)
hoststringYes-IP address or hostname of the device
protocol'http' | 'https'No'http'Protocol to use for communication
portnumberNo80Port number of the device
breakerBreakerOptionsNo-Circuit breaker configuration
retryRetryOptionsNo-Retry strategy configuration
emaEmaOptionsNo-Exponential moving average smoothing

Mock Feed Options ​

OptionTypeRequiredDescription
valueEM1StatusNoFixed EM1 status to return. If omitted, returns undefined

The EM1Status object can contain:

FieldTypeDescription
idnumberEM1 channel ID (0 or 1)
voltagenumberVoltage in V
currentnumberCurrent in A
act_powernumberActive power in W
aprt_powernumberApparent power in VA
pfnumberPower factor
freqnumberFrequency in Hz
calibrationstringCalibration status (e.g., factory)

Examples ​

Basic Setup - Real Shelly Device ​

Proxy a real Shelly Pro EM device without modifications:

yaml
provider: rest
properties:
  port: 3000
  meters:
    grid:
      feed:
        type: http-adapter
        properties:
          device: shelly-pro-em
          host: 192.168.1.100
    solar:
      feed:
        type: http-adapter
        properties:
          device: shelly-pro-em
          host: 192.168.1.101

IMPORTANT

V2C wallbox considers meter ID 0 as grid and 1 as solar. V2C does not allow you to define the port number and uses 80 by default, so make sure to set the correct port in v2c-any configuration.

Mock Solar, Real Grid ​

Use real grid measurements but simulate solar production:

yaml
provider: rest
properties:
  port: 8080
  meters:
    grid:
      feed:
        type: http-adapter
        properties:
          device: shelly-pro-em
          host: 192.168.1.100
    solar:
      feed:
        type: mock
        properties:
          value:
            id: 1
            voltage: 230.5
            current: 10.87
            act_power: 2500
            aprt_power: 2550
            pf: 0.98
            freq: 50
            calibration: factory

High-Availability Configuration ​

Add resilience with circuit breaker, retries, and smoothing:

yaml
provider: rest
properties:
  port: 3000
  meters:
    grid:
      feed:
        type: http-adapter
        properties:
          device: shelly-pro-em
          host: 192.168.1.100
          breaker:
            timeout: 5000
            errorThresholdPercentage: 30
            resetTimeout: 20000
          retry:
            attempts: 5
            minTimeout: 500
            maxTimeout: 30000
          ema:
            alphaRise: 0.3
            alphaFall: 0.5
            alphaMissing: 0.1
            freshnessThreshold: 10000
    solar:
      feed:
        type: off

HTTPS with Custom Port ​

Connect to a Shelly device behind HTTPS on a non-standard port:

yaml
provider: rest
properties:
  port: 3000
  meters:
    grid:
      feed:
        type: http-adapter
        properties:
          device: shelly-pro-em
          host: secure-meter.local
          protocol: https
          port: 8443
    solar:
      feed:
        type: off

Complete Mock Setup (Testing) ​

Simulate both meters for development or testing:

yaml
provider: rest
properties:
  port: 3000
  meters:
    grid:
      feed:
        type: mock
        properties:
          value:
            id: 0
            voltage: 230.0
            current: 15.5
            act_power: 3565
            aprt_power: 3600
            pf: 0.99
            freq: 50
            calibration: factory
    solar:
      feed:
        type: mock
        properties:
          value:
            id: 1
            act_power: 1800
            calibration: factory

Performance ​

  • Polling interval - The V2C wallbox controls how often it polls. Typical intervals are 1-10 seconds.
  • Response time - HTTP adapter feeds add minimal latency (~50-200ms depending on network).
  • Concurrent requests - Fastify server handles multiple simultaneous requests efficiently.
  • Resource usage - Very lightweight (~30-50 MB RAM).

Migration from Physical Shelly ​

To migrate from a physical Shelly Pro EM to v2c-any:

  1. Note your current V2C wallbox configuration (Shelly IP address).
  2. Deploy v2c-any with REST mode on the same IP (or update V2C config).
  3. Configure v2c-any to either:
    • Proxy the existing Shelly (http-adapter feed)
    • Replace it with another data source
    • Use mock data for testing
  4. No changes needed on V2C wallbox if using the same IP address.

Troubleshooting ​

V2C wallbox shows "Meter Offline" ​

Possible causes:

  1. Wrong port configured in V2C wallbox
  2. Firewall blocking connections
  3. v2c-any not running

Solutions:

  • Verify v2c-any is running: check logs or curl http://your-host:port/health
  • Check firewall rules
  • Ensure V2C wallbox can reach the v2c-any host

Getting "Unknown ID" errors ​

The V2C wallbox is requesting a meter ID that isn't configured. Ensure both grid (id=0) and solar (id=1) are configured, even if you set one to type: 'off'.

Power readings are erratic ​

  1. Enable EMA smoothing to reduce fluctuations
  2. Increase freshnessThreshold to use cached values longer
  3. Add retry logic to handle transient network issues

Circuit breaker keeps opening ​

  • Increase timeout value
  • Increase errorThresholdPercentage
  • Increase resetTimeout to give the device more recovery time
  • Check target device health